Alcam performs process control and pre-shipment Final Control activities according to the criteria and tolerances determined by the relevant standards.

In addition, Alcam Quality Engineers test the performance values ​​of the products with devices and equipment in accordance with the standards in Alcam Laboratory.

INSPECTION AND TESTING IN ALCAM:

  • Tempered / Heat Strengthened Glass

According to EN 12150 (Toughend Glass) ve EN 1863 (Heat strengthened glass) Standards:

  • Dimensional Inspections (Width, Length, squareness)
  • Flatness (Overall bow, Roller waves, edge kink)
  • Visual Inspection (Spot Faults, linear faults-scratches, edge-work quality)
  • Tests in the Lab:
    • Smash Test – Fragmentation Test
    • Mechanical Strength Test
  • Laminated Glass

According to EN 12543:

  • Dimensional Inspections (Width, length, squareness, shifting pf the panes)
  • Visual Inspection (Spot Faults, linear faults-scratches, edge-work quality, PVB cleaning quality)
  • Tests in the Lab:
    • Boiling Test
    • High Temperature test in the oven
    • Pummel Test
    • Moisture tests in the moisture cabinet
  • Insulating Glass Unit

According to EN 1279 Standard:

  • Dimensional Inspections (Width, length, squareness)
  • Dimensional Inspections (Width, length, squareness hatalar, stains, coating defects)
  • Application conformity inspections (Continuous butyl, edge deletion quality, spacer orientation)
  • Tests:
    • Sewcondary Sealent conformity tests
    • Primary Sealent (Butyl) conformity tests
    • Molecular Sieve conformity tests
    • Secondary Sealant Adhesion to Glass / Spacer conformity tests

TESTS PERFORMED IN OUR ACCREDITATED PARTNER LABORATORIES:

  • EN 12600 Impact Test and Classification
  • EN 356 Manual Attack Resistance Test and classification
  • EN 1063 Bullet Resistance Test and classification
  • EN 1279-3 Gaz leakage rate and concenteration tolerances test